Watch Batteries, Camcorder Batteries, Remote Control /Specialty batteries, Digital Camera batteries, Cordless Phone batteries, Alkaline Button Cells batteries
Technical Specifications Rayovac Hearing Aid Batteries

Brief description of different kind of batteries | Non-Rechargeable batteries | Sony Watch Batteries | Maxell Lithium Coin Type Batteries | Sony Lithium Coin Type Batteries | Panasonic Lithium Coin Type Batteries | Sony Silver Oxide | LR Micro Alkaline Batteries | Hearing Aid Batteries | GP Rechargable Specialty Batteries | Energizer Hearing Aid Batteries | Energizer Hearing Aid Batteries |
 

Rayovac Corporation
601 Rayovac Drive
Madison WI 53711
Phone: 608-275-3340
Fax: 608-275-4577
http://www.rayovac.com  MATERIAL SAFETY DATA SHEET

1. We would like to inform our customers that these batteries are exempt articles and are not subject to the 29 CFR 1910.1200 OSHA requirement, or to the Canadian WHMIS requirements and the sheets are supplied as a service to you. For other MSDSs and related information, visit: http://www.rayovac.com/customer/msds/msds.shtml .

2. THESE BATTERIES ARE SUITABLE FOR LANDFILL DISPOSAL (SEE SECTION 7).

1. IDENTIFICATION
PRODUCT NAME: Zinc Air Batteries
SIZES: All
EMERGENCY TELEPHONE NUMBER: 800-424-9300 (24 hr, Chemtrec)
Environmental Health & Safety Information: 262-523-9000
EDITION DATE: 03/23/2004 APPROVED BY: Kevin J. Domack

2. INGREDIENTS
INGREDIENT NAME CAS # % TLV*
Zinc 7440-66-6 30 - 40 2 mg/m3 (ZnO, Dust, TWA)
Steel 7439-89-6 30 - 40 ---
Nickel 7440-02-0 3 - 7 1.5 mg/m3 (Elemental, TWA)
Copper 7440-50-8 1 - 5 1 mg/m3 (TWA)
Chromium 7440-47-3 1 - 5 0.5 mg/m3 (Metal, TWA)
Graphite 7782-42-5 1 - 3 2 mg/m3 (TWA)
Potassium Hydroxide 1310-58-3 1 - 3 C 2 mg/m3 (STEL)
Mercury 7439-97-6 < 1** 0.025 mg/m3 (Inorganic, TWA)
Water, paper, plastic, other --- Balance ---
*Source: ACGIH Threshold Limit Values for Chemical Substances and Physical Agents, 2003.
** Zinc Air Batteries contain less than 25 mg/cell of mercury.

3. PHYSICAL DATA
Boiling Point @ 760 mm Hg (°C): NA
Vapor Pressure (mm Hg @ 25°C): NA
Vapor Density (Air = 1): NA
Density (grams/cc): NA
Percent Volatile by Volume (%): NA
Evaporation Rate (Butyl Acetate = 1): NA
Physical State: NA
Solubility in Water (% by Weight): NA
pH: NA
Appearance and Odor: geometric solid object, this battery has several holes in the positive (+) end
NA = Not Applicable Zinc Air Batteries - 03-23-2004 Page 2 of 3

4. FIRE & EXPLOSION HAZARD DATA
FLASH POINT: NA LOWER (LEL): NA
FLAMMABLE LIMITS IN AIR (%): NA UPPER (UEL): NA
EXTINGUISHING MEDIA: Use water, foam or dry powder, as appropriate.
AUTO-IGNITION: NA
SPECIAL FIRE FIGHTING PROCEDURES: As with any fire, wear self-contained breathing apparatus to avoid inhalation o
 hazardous decomposition products (See section 2).
SPECIAL FIRE EXPLOSION HAZARDS: Like any sealed container, battery cells may rupture when exposed to excessive heat; this could result in the release of flammable or corrosive materials.

5. HEALTH HAZARD DATA
THRESHOLD LIMIT VALUE (TLV) AND SOURCE: NA
EFFECTS OF OVEREXPOSURE: None. (In fire or rupture situation see section 2 and section 4)
EMERGENCY FIRST AID PROCEDURES:

Skin and Eyes:
In the event that battery ruptures, flush exposed skin with copious quantities of flowing lukewarm water for a minimum of 15 minutes. Get immediate medical attention for eyes. Wash skin with soap and water.

Swallowing:
Ingestion of a battery can be harmful. Call The National Capital Poison Control Center (202-625-3333 –
COLLECT) or your local Poison Control Center (800-222-1222), day or night - for advice and follow-up.
For more information, visit:
http://www.nema.org/index_nema.cfm/666.

6. REACTIVITY DATA
STABLE OR UNSTABLE: Stable
INCOMPATIBILITY (MATERIALS TO AVOID): NA
HAZARDOUS DECOMPOSITION PRODUCTS: NA
DECOMPOSITION TEMPERATURE (0°F): NA
HAZARDOUS POLYMERIZATION: Will Not Occur
CONDITIONS TO AVOID: Avoid electrical shorting.
NA = Not Applicable Zinc Air Batteries

7. SPILL OR LEAK PROCEDURES
PROCEDURES TO CONTAIN AND CLEAN UP LEAKS OR SPILLS: In the event of a battery rupture, prevent skin contact and collect all released material in a plastic lined metal container.
REPORTING PROCEDURE: Report all spills in accordance with Federal, State and Local reporting requirements.
WASTE DISPOSAL METHOD: Rayovac Zinc Air batteries, subject to Toxic Characteristic Leaching Procedures (TCLP) per U.S. EPA Method SW-846, have not shown hazardous waste characteristics. Therefore the batteries are non-hazardous generated waste per federal regulations. Some States or local rules may require specific waste management methods. Collection is required in European Union Countries. For additional info. on disposal/reclaim options, visit:
http://www.rayovac.com/about/environmental/e_faq.shtml.

8. PROTECTION INFORMATION
RESPIRATORY PROTECTION (SPECIFY TYPE): NA
VENTILATION: Local Exhaust: NA
Mechanical (General): NA
Special: NA
Other: NA
PROTECTIVE GLOVES: NA
EYE PROTECTION: NA
OTHER PROTECTIVE CLOTHING: NA

9. SPECIAL PRECAUTIONS
HANDLING AND STORAGE: Store in a dry place. Storing unpackaged cells together could result in cell shorting and heat build-up.
TRANSPORTATION-SHIPPING: These are "batteries, dry" and are not considered to be a "hazardous material" per the Dept. of Transportation (USDOT) regulations or "dangerous goods" per the International Air Transport Association (IATA) regulations. Shipments must comply with the general duty clause of USDOT 49 CFR 172.102 (a) (1) special provision 130, “to prevent shorting potential while transporting.”

10. SARA 313
Notification is not required because these products are article(s) that do not release a covered toxic chemical under the normal conditions of processing or use.

NOTICE: The information and recommendations set forth are made in good faith and are believed to be accurate at the date of preparation. Rayovac Corporation makes no warranty expressed or implied.

 

 

HOME | COMPANY | PRODUCTS | TECH SPECS | FAQS | LINKS | PAYMENT | POLICIES | CONTACT US | E-MAIL US

Copyright 2005 CH Batteries - All Rights Reserved - Logos are property of their respective owners - Web Development paginadigital.com.ar
 
Credit card payments on this website are processed by Pay Pal Secure Transaction System. PayPal uses SSL technology to keep your information safe. In addition, when you send a payment using PayPal, the recipient won't receive sensitive financial information like your credit card or bank account number. This way, you don't have to worry about paying people you don't know. Also you don't need to have a Pay Pal account, just go through Checkout and pay simply, fast and secure.
Cellular Phone Batteries (Cellular Telephone Battery Packs)
Camcorders Batteries (Rechargeable Battery Pack for Camcorders)
Digital Camera Batteries ( Battery Packs for Digital Cameras)
Cordless Phone Batteries (NiCd and Ni-MH packs)
Rechargeable Batteries (Ni-Cd and NiMh cells)
Ni-Cd and Ni-MH cylindrical Batteries (AA, AAA, C, Sub-C, D, 9v, etc)
Photo Lithium Batteries (Batteries for Photo Cameras)
Watch Batteries (Silver Oxide Button Cells)
Alkaline Button Batteries (Alkaline Button Cells)
Lithium Coin Type Batteries (Batteries for Calculators, Watch, etc)
Remote Control Batteries / Medical and Special Uses Batteries
Hearing Aid Batteries (Air-Zinc 1.4v Batteries)